Dual Output Isolated Current Voltage Input Output Repeater
Dual Output Isolated Current Voltage Input Output Repeater
Dual Output Isolated Current Voltage Input Output Repeater
Dual Output Isolated Current Voltage Input Output Repeater
Dual Output Isolated Current Voltage Input Output Repeater
Dual Output Isolated Current Voltage Input Output Repeater
Dual Output Isolated Current Voltage Input Output Repeater
Dual Output Isolated Current Voltage Input Output Repeater
Dual Output Isolated Current Voltage Input Output Repeater
Dual Output Isolated Current Voltage Input Output Repeater
Dual Output Isolated Current Voltage Input Output Repeater
Dual Output Isolated Current Voltage Input Output Repeater

Dual Output Isolated Current Voltage Input Output Repeater

Price 2000.0 INR/ Unit

MOQ : 10 Units

Dual Output Isolated Current Voltage Input Output Repeater Specification

  • Application
  • Commercial
  • Protection Level
  • IP54
  • Output Type
  • Multiple
  • Color
  • Different Available
  • Warranty
  • Yes
 

Dual Output Isolated Current Voltage Input Output Repeater Trade Information

  • Minimum Order Quantity
  • 10 Units
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 10 Days
  • Main Domestic Market
  • All India
 

Dual Output Isolated Current Voltage Input Output Repeater About

A Dual Output Isolated Current/Voltage Input/Output Repeater (commonly 4-20mA or 0-10V) is an industrial signal conditioner that takes a single input signal and provides two electrically isolated, independent, and precise output signals. It protects sensitive, low-voltage control systems (PLC/SCADA) from high-voltage transients, eliminates ground loops, and drives long cable runs.
Key Features and Technical Description
  • Isolation: Typically offers 3-port or 4-port isolation (input, output 1, output 2, and power supply) up to 2000V AC or higher to prevent interference.
  • Inputs/Outputs: Accepts standard analog signals like 4-20mA, 0-20mA, 0-10V, or 0-5V. Dual output means it can "split" one input signal into two identical, isolated outputs (e.g., sending to a recorder and a PLC simultaneously).
  • Power Supply: Generally requires a 24V DC nominal supply, with some models offering 85-265V AC/DC compatibility.
  • Accuracy & Performance: High-precision, with typical accuracy of $pm$0.1% of span and linearity of $pm$0.02%, ensuring signal integrity.
  • Mounting & Dimensions: Compact design (often 22.5 mm width) suitable for 35 mm DIN-rail mounting.
  • Functionality: Can work as a repeater (1-in, 2-out), an isolator (1-in, 1-out), or a converter (voltage in, current out), often configurable by switches.
Common Applications
  • Signal Splitting: Sending one transmitter signal to two different controllers.
  • Ground Loop Elimination: Breaking ground connections between field instruments and control rooms.
  • Field Instrument Powering: Acting as a power supply for 2-wire, 4-20mA transmitters.
This device is essential for ensuring robust, noise-free analog signal transmission in factories and process automation environments.


Reliable Signal Isolation for Commercial Spaces

Ensure your automation and control systems maintain top performance with our Dual Output Isolated Current Voltage Input Output Repeater. Designed for commercial use, it efficiently isolates and duplicates signals, minimizing interference and enhancing operational stability. Its IP54-rated enclosure guarantees protection from dust and water splashes, making it suitable for challenging environments.


Versatile Outputs and Adaptable Application

This device offers multiple output options, supporting a variety of commercial applications. Its design accommodates different installation settings, with color options enabling easy integration into existing system aesthetics. As a trusted manufacturer and supplier based in India, we deliver customized solutions built on proven reliability.

FAQ's of Dual Output Isolated Current Voltage Input Output Repeater:


Q: How does the Dual Output Isolated Current Voltage Input Output Repeater function in a control system?

A: The repeater isolates and duplicates input signals, ensuring accurate and interference-free current or voltage transmission between devices. This improves safety and system reliability in commercial automation and monitoring.

Q: What types of outputs does this repeater provide?

A: It supports multiple output types, allowing flexibility for various commercial applications, such as both current and voltage signal outputs tailored to your system's requirements.

Q: When should I consider using this repeater in my setup?

A: This device is essential when your control system requires electrical isolation between input and output, especially in environments prone to electrical noise or potential ground loops.

Q: Where can the Dual Output Isolated Repeater be installed safely?

A: With its IP54 protection level, the repeater can be safely installed in commercial environments where it may be exposed to dust and water splashes, but it should not be submerged or directly exposed to heavy water jets.

Q: What is the process for ordering and installing the repeater in India?

A: As a manufacturer and supplier in India, we offer streamlined ordering and support. After purchase, simple mounting and wiring instructions are provided for quick integration into your system.

Q: How is the warranty for this product managed?

A: Each repeater comes with a manufacturer's warranty. In case of defects or issues, simply contact our support team for repairs or replacement in accordance with warranty terms.

Q: What are the benefits of using this repeater in a commercial application?

A: It enhances safety, reduces interference, and protects sensitive equipment by electrically isolating signals, ensuring optimal performance and longevity for your commercial control systems.